可提供此產(chǎn)品的更新版本

功能與比較器件相同,但引腳排列有所不同
BQ40Z80 正在供貨 采用 Impedance Track? 電量測(cè)量技術(shù)的 2 節(jié)至 6 節(jié)電池包管理器 SHA-1 authentication, TURBO mode 2.0, black box recorder, adaptive charging

產(chǎn)品詳情

Cell chemistry Li-Ion/Li-Polymer Number of series cells 2-4 Cells, >4 Cells Communication interface SMBus Battery capacity (min) (mAh) 1000 Battery capacity (max) (mAh) 327670 Implementation Pack External capacity indication EPD, LCD Features Coulomb Counter Operating temperature range (°C) -40 to 85 Rating Catalog
Cell chemistry Li-Ion/Li-Polymer Number of series cells 2-4 Cells, >4 Cells Communication interface SMBus Battery capacity (min) (mAh) 1000 Battery capacity (max) (mAh) 327670 Implementation Pack External capacity indication EPD, LCD Features Coulomb Counter Operating temperature range (°C) -40 to 85 Rating Catalog
VQFN (RGZ) 48 49 mm2 7 x 7
  • bq78PL114 Designed for Managing 3- to 8-Series-Cell Battery Systems
  • bq78PL114S12 Firmware Upgrade Supports 3- to 12-Series-Cell Battery Systems
    • Adds Support for LCD and Electronic Paper Displays or EPDs
    • Configurable for 11-A, 26-A, or 110-A Operating Currents
  • Systems With More Than Four Series Cells Require External bq76PL102 Dual-Cell Monitors
  • SmartSafety Features:
    • Prevention: Optimal Cell Management
    • Diagnosis: Improved Sensing of Cell Problems
    • Fail Safe: Detection of Event Precursors
  • Rate-of-Change Detection of All Important Cell Characteristics:
    • Voltage
    • Impedance
    • Cell Temperature
  • PowerPump Technology Transfers Charge Efficiently From Cell to Cell During All Operating Conditions, Resulting in Longer Run Time and Cell Life
    • bq78PL114S12 Adds User-Configurable PowerPump Cell-Balancing Modes
  • High-Resolution 18-Bit Integrating Delta-Sigma Coulomb Counter for Precise Charge-Flow Measurements and Gas Gauging
  • Multiple Independent ADCs: One-per-Cell Voltage, Plus Separate Temperature, Current, and Safety
  • Simultaneous, Synchronous Measurement of Pack Current and Individual Cell Voltages
  • Very Low Power Consumption
    • bq78PL114: < 250 μA Active, < 150 μA Standby, < 40 μA Ship, and < 1 μA Undervoltage Shutdown
    • bq78PL114S12: < 300 μA Active, < 185 μA Standby, < 85 μA Ship, and < 1 μA Undervoltage Shutdown
  • Accurate, Advanced Temperature Monitoring of Cells and MOSFETs With up to 12 Sensors
  • Fail-Safe Operation of Pack Protection Circuits: Up to Three Power MOSFETs and One Secondary Safety Output (Fuse)
  • Fully Programmable Voltage, Current, Balance, and Temperature-Protection Features
  • External Inputs for Auxiliary MOSFET Control
  • Smart Battery System 1.1 Compliant via SMBus
  • APPLICATIONS
    • Portable Medical Instruments and Test Equipment
    • Mobility Devices (E-Bike)
    • Uninterruptible Power Supplies and Hand-Held Tools

PowerLAN, PowerPump, bqWizard are trademarks of Texas Instruments.
All other trademarks are the property of their respective owners.

  • bq78PL114 Designed for Managing 3- to 8-Series-Cell Battery Systems
  • bq78PL114S12 Firmware Upgrade Supports 3- to 12-Series-Cell Battery Systems
    • Adds Support for LCD and Electronic Paper Displays or EPDs
    • Configurable for 11-A, 26-A, or 110-A Operating Currents
  • Systems With More Than Four Series Cells Require External bq76PL102 Dual-Cell Monitors
  • SmartSafety Features:
    • Prevention: Optimal Cell Management
    • Diagnosis: Improved Sensing of Cell Problems
    • Fail Safe: Detection of Event Precursors
  • Rate-of-Change Detection of All Important Cell Characteristics:
    • Voltage
    • Impedance
    • Cell Temperature
  • PowerPump Technology Transfers Charge Efficiently From Cell to Cell During All Operating Conditions, Resulting in Longer Run Time and Cell Life
    • bq78PL114S12 Adds User-Configurable PowerPump Cell-Balancing Modes
  • High-Resolution 18-Bit Integrating Delta-Sigma Coulomb Counter for Precise Charge-Flow Measurements and Gas Gauging
  • Multiple Independent ADCs: One-per-Cell Voltage, Plus Separate Temperature, Current, and Safety
  • Simultaneous, Synchronous Measurement of Pack Current and Individual Cell Voltages
  • Very Low Power Consumption
    • bq78PL114: < 250 μA Active, < 150 μA Standby, < 40 μA Ship, and < 1 μA Undervoltage Shutdown
    • bq78PL114S12: < 300 μA Active, < 185 μA Standby, < 85 μA Ship, and < 1 μA Undervoltage Shutdown
  • Accurate, Advanced Temperature Monitoring of Cells and MOSFETs With up to 12 Sensors
  • Fail-Safe Operation of Pack Protection Circuits: Up to Three Power MOSFETs and One Secondary Safety Output (Fuse)
  • Fully Programmable Voltage, Current, Balance, and Temperature-Protection Features
  • External Inputs for Auxiliary MOSFET Control
  • Smart Battery System 1.1 Compliant via SMBus
  • APPLICATIONS
    • Portable Medical Instruments and Test Equipment
    • Mobility Devices (E-Bike)
    • Uninterruptible Power Supplies and Hand-Held Tools

PowerLAN, PowerPump, bqWizard are trademarks of Texas Instruments.
All other trademarks are the property of their respective owners.

The bq78PL114 master gateway battery controller is part of a complete Li-Ion control, monitoring, and safety solution designed for large series cell strings.

The bq78PL114 and bq78PL114S12 along with bq76PL102 PowerLAN™ dual-cell monitors provide complete battery-system control, communications, and safety functions for a structure of three up to twelve series cells. This PowerLAN system provides simultaneous, synchronized voltage and current measurements using one A/D per-cell technology. This eliminates system-induced noise from measurements and allows the precise, continuous, real-time calculation of cell impedance under all operating conditions, even during widely fluctuating load conditions.

PowerPump technology transfers charge between cells to balance their voltage and capacity. Balancing is possible during all battery modes: charge, discharge, and rest. Highly efficient charge-transfer circuitry nearly eliminates energy loss while providing true real-time balance between cells, resulting in longer run-time and improved cycle life.

Temperature is sensed by up to 12 external sensors and one on-chip sensor. This permits accurate temperature monitoring of each cell individually. Firmware is then able to compensate for the temperature-induced effects on capacity, impedance, and OCV on a cell-by-cell basis, resulting in superior charge/ discharge and balancing control.

External MOSFET control inputs provide user- definable direct hardware control over MOSFET states. Smart control prevents excessive current through MOSFET body diodes. Auxiliary inputs can be used for enhanced safety and control in large multicell arrays.

The bq78PL114 is completely user-configurable, with parametric tables in flash memory to suit a variety of cell chemistries, operating conditions, safety controls, and data reporting needs. It is easily configured using the supplied bqWizard graphical user interface (GUI). The device is fully programmed and requires no algorithm or firmware development.

The bq78PL114 can be upgraded to the bq78PL114S12 by downloading the bq78PL114S12 firmware. The firmware can be downloaded using the bqWizard application or during manufacturing. Upgrading to the bq78Pl114S12 changes the functionality of the LED1-LED5, LEDEN, and N/C pin #29. The bq78PL114S12 pin functions of LED1/SEG1-LED5/SEG5, PSH/BP/TP, and FIELD support LED, LCD, and electronic paper displays (EPDs). The user can configure the bq78PL114S12 for the desired display type.

In this document all descriptions for the bq78PL114 apply to the bq78PL114S12 except where different bq78PL114S12 functionality is specifically described.

The bq78PL114 master gateway battery controller is part of a complete Li-Ion control, monitoring, and safety solution designed for large series cell strings.

The bq78PL114 and bq78PL114S12 along with bq76PL102 PowerLAN™ dual-cell monitors provide complete battery-system control, communications, and safety functions for a structure of three up to twelve series cells. This PowerLAN system provides simultaneous, synchronized voltage and current measurements using one A/D per-cell technology. This eliminates system-induced noise from measurements and allows the precise, continuous, real-time calculation of cell impedance under all operating conditions, even during widely fluctuating load conditions.

PowerPump technology transfers charge between cells to balance their voltage and capacity. Balancing is possible during all battery modes: charge, discharge, and rest. Highly efficient charge-transfer circuitry nearly eliminates energy loss while providing true real-time balance between cells, resulting in longer run-time and improved cycle life.

Temperature is sensed by up to 12 external sensors and one on-chip sensor. This permits accurate temperature monitoring of each cell individually. Firmware is then able to compensate for the temperature-induced effects on capacity, impedance, and OCV on a cell-by-cell basis, resulting in superior charge/ discharge and balancing control.

External MOSFET control inputs provide user- definable direct hardware control over MOSFET states. Smart control prevents excessive current through MOSFET body diodes. Auxiliary inputs can be used for enhanced safety and control in large multicell arrays.

The bq78PL114 is completely user-configurable, with parametric tables in flash memory to suit a variety of cell chemistries, operating conditions, safety controls, and data reporting needs. It is easily configured using the supplied bqWizard graphical user interface (GUI). The device is fully programmed and requires no algorithm or firmware development.

The bq78PL114 can be upgraded to the bq78PL114S12 by downloading the bq78PL114S12 firmware. The firmware can be downloaded using the bqWizard application or during manufacturing. Upgrading to the bq78Pl114S12 changes the functionality of the LED1-LED5, LEDEN, and N/C pin #29. The bq78PL114S12 pin functions of LED1/SEG1-LED5/SEG5, PSH/BP/TP, and FIELD support LED, LCD, and electronic paper displays (EPDs). The user can configure the bq78PL114S12 for the desired display type.

In this document all descriptions for the bq78PL114 apply to the bq78PL114S12 except where different bq78PL114S12 functionality is specifically described.

下載 觀看帶字幕的視頻 視頻

技術(shù)文檔

star =有關(guān)此產(chǎn)品的 TI 精選熱門(mén)文檔
未找到結(jié)果。請(qǐng)清除搜索并重試。
查看全部 10
頂層文檔 類(lèi)型 標(biāo)題 格式選項(xiàng) 下載最新的英語(yǔ)版本 日期
* 數(shù)據(jù)表 PowerLAN Gateway Battery Management Controller with PowerPump Cell Balancing 數(shù)據(jù)表 (Rev. B) 2009年 4月 30日
應(yīng)用手冊(cè) Wide-Vin Battery-Charger Using SMBus MSP430 MCUs and bq Fuel Gauges (Rev. B) PDF | HTML 2019年 7月 12日
應(yīng)用手冊(cè) PowerPump(TM) Balancing (Rev. B) 2011年 10月 26日
應(yīng)用手冊(cè) SBData Commands For PowerLAN(TM) Master Gateway Controller 2011年 4月 14日
應(yīng)用手冊(cè) What is a .tmap File? (Rev. A) 2011年 3月 10日
用戶指南 bq78PL114 and bq78PL114S12 Technical Reference Manual (Rev. B) 2010年 5月 25日
應(yīng)用手冊(cè) Quick-Start Guide for BQ78PL114 with BQ76PL102 Family Gas Gauges 2010年 4月 26日
應(yīng)用手冊(cè) Chemistry Selection for the bq78PL114 (Rev. B) 2010年 2月 12日
應(yīng)用手冊(cè) bq78PL114 System Design Guidelines 2009年 12月 1日
應(yīng)用手冊(cè) Configuring the bq78PL114 Cell Count (Rev. A) 2009年 5月 20日

設(shè)計(jì)與開(kāi)發(fā)

如需其他信息或資源,請(qǐng)點(diǎn)擊以下任一標(biāo)題進(jìn)入詳情頁(yè)面查看(如有)。

應(yīng)用軟件和框架

BQ78PL11XAPI-SW bq78PL11X Application Programming Interface Software

This Application Programming Interface (API) is designed to support the production flow ofa PowerLAN Master Gateway controller based hardware. The methods provide a rich interfacefor calibrating, configuring, and updating firmware. This API is built on the .NET framework andcontains a COM visible (...)

支持的產(chǎn)品和硬件

支持的產(chǎn)品和硬件

固件

USB2GPIO-LOADER-SW — USB-TO-GPIO EVM 固件加載程序

USB-TO-GPIO EVM 附帶了一個(gè)與 HCE-BMS 產(chǎn)品 (bq78PL114) 不兼容的固件。USB-TO-GPIO EVM 必須進(jìn)行重新編程以實(shí)現(xiàn)與 BMS-HCE 器件配合使用。此固件加載程序用于改造 USB-TO-GPIO EVM 中的固件,從而使其可與 bq78PL114EVM 一起使用。
支持軟件

BQWIZARD bqWizard Setup Version 3.1

The bqWizard™ application software allows the user to evaluate the condition, or state, of the battery Pack and Cells in the system. This software gives detailed insight into the workings of evaluation modules and user custom battery packs. The software is used to configure and setup (...)

支持的產(chǎn)品和硬件

支持的產(chǎn)品和硬件

封裝 引腳 CAD 符號(hào)、封裝和 3D 模型
VQFN (RGZ) 48 Ultra Librarian

訂購(gòu)和質(zhì)量

包含信息:
  • RoHS
  • REACH
  • 器件標(biāo)識(shí)
  • 引腳鍍層/焊球材料
  • MSL 等級(jí)/回流焊峰值溫度
  • MTBF/時(shí)基故障估算
  • 材料成分
  • 鑒定摘要
  • 持續(xù)可靠性監(jiān)測(cè)
包含信息:
  • 制造廠地點(diǎn)
  • 封裝廠地點(diǎn)

支持和培訓(xùn)

可獲得 TI 工程師技術(shù)支持的 TI E2E? 論壇

所有內(nèi)容均由 TI 和社區(qū)貢獻(xiàn)者按“原樣”提供,并不構(gòu)成 TI 規(guī)范。請(qǐng)參閱使用條款。

如果您對(duì)質(zhì)量、包裝或訂購(gòu) TI 產(chǎn)品有疑問(wèn),請(qǐng)參閱 TI 支持。??????????????

視頻